The hazardous world of Ex Marking

Coding for equipment used in explosive atmospheres

By Ron Sinclair MBE, Chair of European Committee for Electrotechnical Standardization (CENELEC) CLC/TC 31: Electrical apparatus for potentially explosive atmospheres, member of Working Group (WG) 22 of IEC TC 31: Equipment for explosive atmospheres, IECEEx Ex Service Facility Committee (ExSFC) Chair

This article was first published in HazardEx on 20 April 2017 - subheadings and "About IECEx" section were inserted editorially by IEC

The one subject guaranteed to get everyone hot under the collar is the subject of the marking of Ex Equipment. There is not much disagreement about the need to identify the equipment type, its operational parameters and its manufacturer, but everyone seems to have an opinion on how the hazardous area code should be expressed. The discussions at the recent IEC TC 31: Equipment for explosive atmospheres, standards meetings in Sydney, Australia, were no exception, and we will return to this later. But first, we need an historical perspective.

IECEx/ATEX marking IECEx and ATEX markings - the first line refers to ATEX marking only (Image: Transtek)

Historical perspective

In the beginning there was only the need to confirm that a piece of equipment was intended to be installed in a hazardous area. It was pretty obvious if it was either flameproof or intrinsically safe, and everybody knew the difference.

Then we started to divide our hazardous areas according to how severe we thought the hazard might be: originally into Divisions (still maintained in the USA) and then Zones, with Zone 0 indicating the greatest risk and Zone 2 the least risk. Flameproof protection was originally IEC 60079, but as it was later decided to put all the forms of protection in the same series, flameproof became IEC 60079-1, with the other concepts and ideas forming subsequent part numbers, until we are now talking about introducing IEC 60079-40 With each new type of protection, a letter “code” was allocated, so that people operating on a plant would be able to tell the type of protection and be able to inspect and maintain accordingly.

This letter code was used to determine the suitability of a particular item of equipment for installation in a given zone. Simple – or at least, it was at first.

Now we have single standards covering individual types of protection, but for various levels of protection, so the letter “m” for encapsulation, for example, is always followed by a second letter indicating the level of protection, giving us “ma”, “mb” or “mc”. 

Several forms of protection

Equipment now is more commonly protected by more than one form of protection. For example a typical fluorescent luminaire may have the lamps and terminals protected by increased safety “e” with the ballast encapsulated “m” or powder filled “q”, while the isolating switch is flameproof “d”.

For a long time, there was an argument whether the first letter should represent the type of protection applied to the wiring terminals, or should represent the protection applied to the largest part of the equipment. Eventually, the decision was taken that the letters would be listed in alphabetical order so that no one would be able to read the wrong significance into that order.

It was also agreed that the equipment would be marked with the Equipment Protection Level (EPL) a single, short form two-letter designator that explicitly indicated the overall level of protection and, therefore, the Zone for which it was most suitable. The current published edition of IEC 60079-0:2011 also requires that marking for hazardous gas or vapour atmospheres and marking for hazardous dust atmospheres should not be combined. This is to indicate two separate possible uses of the equipment, and not that the equipment is suitable for use in a hybrid mixture of gas and dust. 

First IECEx certificates issued for non-electrical equipment

Which brings us back to the Sydney discussion. With the publication of ISO 80079-36 and ISO 80079-37, we now have IECEx certificates issued for the first time for non-electrical equipment. The symbol “h” has been allocated to indicate the protection of non-electrical equipment, whatever the detailed method applied.

The marking from EN 13463-1 could not be used at the international level, since it was intertwined with the legal marking of the ATEX Directive. Although used as shorthand within the standards, the letters “c” constructional safety, “b” control of ignition sources and “k” liquid immersed, do not appear as part of the marking.

When a single item of equipment with both electrical and non-electrical protection is considered, questions arise how it should be coded. There is a view that the electrical and non-electrical marking should not be mixed, with two separate lines of code used (as with a product suitable for use in either a gas or a dust hazard).

I do not subscribe to that view, but consider that there should be just one line of code, with the letter “h” taking its alphabetical place in the marking string. That way, there will just be one EPL, one Group and one Temperature Class marked, putting the potential use of the equipment beyond doubt.

About IECEx

IECEx, the IEC System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres, is the only truly international Conformity Assessment (CA) System to provide testing and certification for all items of electrical and non-electrical Ex equipment and installations as well as certifying the skills and competence of individuals working in hazardous areas. 

The System addresses the inspection (location and other), installation, maintenance and repair of equipment and systems and assesses the competence of personnel working in this highly-specialized area. 

IECEx has been endorsed by the United Nations (UN) through the UN Economic Commission for Europe (UNECE) as THE certification system for the assessment of conformity in Ex areas. 

IECEx operates the following Schemes: 

  • IECEx Certified Equipment Scheme
  • IECEx Certified Service Facilities Scheme
  • IECEx Scheme for Certification of Personnel Competence (for Explosive Atmospheres)

The System also has the IECEx Conformity Mark Licensing System which provides on-the-spot evidence that products bearing the Conformity Mark are covered by an IECEx Certificate of Conformity. 

More information: www.iecex.com